8. PLUMBING SYSTEMS FOR SOLAR HEATING


There are two main choices for how to arrange the plumbing in the solar loop, Drainback and Pressurised:

Drainback solar system

When the pump is not running in a drainback solar system, all of the liquid is inside the building and the solar panels are empty of fluid. A small tank (the drainback vessel) holds the liquid so that the resting fill level is above the pump.

When the pump is not running in a drainback solar system, the fluid rests at a level inside the building and the solar panel is empty When the pump is running the panel is filled with liquid and the level in the drainback vessel is lower than the resting level
Drainback system with pump off and
fluid at the rest level
Drainback system with pump running

If there is heat to be collected from the solar panel, the pump is energised by the solar controller, and starts to push liquid up and over the top of the circuit. The level of fluid in the drainback vessel goes downuntil the point where liquid has filled all of the pipework above the drainback vessel. The circuit is now complete and heat is transferred from the solar panel to the hot water cylinder.

When the pump switches off (for example at night time or if the cylinder reaches its target temperature), the fluid flows backwards under gravity down the solar panel, refilling the drainback vessel. This arrangement protects the solar fluid from temperature extremes that can occur overnight in winter and during "stagnation" in summer.

Stagnation is the condition when the pump is switched off during sunny weather (for example because the hot water store is already at its maximum temperature). With no circulation of solar fluid to cool the panel, it gets hotter and hotter. In full sun high performance solar panels will reach an equilibrium point (where heat losses balance with solar energy gain) at an internal temperature greater than 200C.

The advantages of the drainback solar system are:

  • It is simple to install and maintain because filling it up is as simple as pouring the liquid in.
  • The solar fluid is kept in the building overnight, preventing freezing in the solar panel
  • The solar circuit is protected against high temperatures and pressures which occur in stagnation

Pressurised solar system

In a pressurised solar system, the solar circuit is completely filled with liquid at all times, including overnight in freezing weather and during periods of stagnation. To prevent bursting of frozen pipes in the solar panel the circuit is filled with antifreeze solution, around 40% by weight of propylene glycol will protect the solar panels down to -20C.

The volume of the solar fluid will change as its temperature changes, expanding when it heats up and contracting when it cools down, similar to unvented heating systems. Consequently an expansion vessel needs to be incorporated into the system to accommodate these changes in volume without creating extreme pressures.

A pressurised system needs an expansion vessel to accommodate changes in volume of the fluid as its temperature changes In stagnation, the entire volume of the pipes in the solar panel will be turned to steam, diplacing liquid into the expansion vessel
Pressurised system with pump running
Pressurised system in stagnation condition -
no circulation with solar panel in sunshine

In stagnation the temperature in the panel is high enough to boil the solar fluid. As it changes to steam the fluid undergoes a massive change in volume, so fluid is pushed out of the panel and into the expansion vessel.

During commissioning it is necessary to expel all of the air from the system and charge it up with a solution of antifreeze. This is normally done with a special filling pump that can chase the solar fluid around the system at high velocity and sweep the air out. As a result, commissioning and maintaining a pressurised system is a more complex and time consuming job than for a drainback system.

The advantage of the pressurised system over the drainback system is that it is applicable to a wider range of situations. The drainback pump needs to be installed within a certain height below from the highest point in the system, and the pipes to and from the solar panel need to be installed with a fall to allow drainage. In addition, the volume in the drainback vessel limits the allowable volume of pipe above it, therefore the length of pipe runs and number of solar panels that can be run from a drainback vessel of a particular size.

Special Requirements for Solar Plumbing

A re-start of the solar pump following a stagnation will result in steam being pushed out of the solar panel and down the pipes to the cylinder for both drainback and pressurised systems. The steam quenches rapidly on the cooler pipework, but instantaneous temperatures greater than 200C can be reached, especially near the solar panel inlet and outlet pipes.

The temperatures reached in stagnation mean that the solar pipework needs to be robust in the face of steam at elevated pressures. Certain types of insulation, solder and pipe materials need to be avoided in solar plumbing circuits:

  • Pipes can be copper or stainless steel. Conventional plastic heating pipes must not be used in a solar loop.
  • Insulation can be foamed rubber, mineral fibre, or rigid polyurethane but not foamed polyethylene (a common material for standard heating systems).
  • Standard solder will soften at such high temperatures. Joints should be made with compression fittings with a high-temperature solder.